Item code | C1-055HFC |
Supply voltage | 3 phase: 380V-15% to 240V +10% |
Output voltage | 3Phase 380-400VAC |
Rated output current | 14.8A |
Supply frequency | 50/60 Hz fluctuation amplitude ± 5% |
Power | 5500W |
Overload capacity | 150% 60 giây |
Starting torque | 200% tại 0,5Hz (điều khiển vector không cảm biến) |
Carrier frequency range | 2kHz-15kHz |
Settable frequency range | 0.1Hz-400Hz |
Input frequency resolution | Digital : ± 0,01% Analogue: ± 0,2% (25 ° C ± 10 ° C) |
Display | Led 7 segments (5 digit) |
Acceleration/Deceleration time | 0.1-3600 seconds |
Frequency setting | Control panel: set value by keyboard, internal resistor External signal: 0 to 10 VDC (input impedance 10kΩ), 4 to 20mA (input impedance 100Ω), Potentiometer (1k to 2kΩ, 2W) Communication: RS485 ModBus RTU, other network options |
Forward/Reverse running | Control panel: Run/Stop (Forward/Reverse changes by command) External signal: Forward run/stop, Reverse run/stop Communication: RS485 ModBus RTU, other network options Terminals: 7 terminals, source/sink can be changed with a short bar |
Other functions | V/f control, manual/automatic torque boost, output voltage boost adjustment, AVR function, starting voltage reduction, motor data selection, auto-tuning, motor stability control, reverse running protection, simple position control, simple torque control, torque limit, automatic carrier frequency reduction, energy-saving operation, PID function, non-stop operation during instantaneous power failure, brake control, DC injection brake, dynamic brake (BRD), upper and lower frequency limits, frequency jump, increase and decel curve (S, U, U reverse, EL-S), 16-stage speed configuration, fine adjustment of starting frequency, increasing and decreasing stop speed, jogging process, frequency calculation, frequency supplement, 2-stage speed increase/decrease, stop mode selection, start/end frequency., analog input filter, window comparator, input response time input, output signal delay/hold function, rotation direction limit, stop key selection, software lock, safe stop function, scaling function, display limit, function password, user parameter, initialization, initial display selection, cooling fan control, warning, trip retry, pull-in frequency restart, frequency matching, overload limit, overcurrent limit, AVR DC bus voltage |
Input other functions | FW (forward run command), RV (reverse run command), CF1 - CF4 (multi-stage speed setting), JG (fast run command), DB (external brake), SET (second motor set), 2CH (2-stage acceleration ./decel. command), FRS (free run stop command), EXT (external trip), USP (start function), CS (commercial power switch), SFT (soft lock), AT (analog input selection), RS (reset), PTC (thermal resistance protection), STA (start), STP (stop), F/R (forward/reverse), PID (PID off), PIDC (PID reset), UP (remote control function), DWN (remote control function down), UDC (remote control data erase), OPE (operator control), SF1 - SF7 (multi-stage speed setting; operation bit), OLR (overload limit), TL (torque limit enable), TRQ1 (torque limit switch1), TRQ2 (torque limit switch2), BOK (brake acknowledge), LAC (LAD cancel), PCLR (position deviation clear), ADD (frequency add enable), F-TM (force mode connector), ATR (torque command input enable), KHC (accumulated power clear), MI1 – MI7 (general purpose input for EzSQ), AHD (analog command hold), CP1– CP3 (multi-stage position switch), ORL (zero return signal limit), ORG (zero return enable signal), SPD (speed/position switching), GS1, GS2 (STO input, safety related signal), 485 (start communication signal), PRG (execute EzSQ program), HLD (frequency hold output number), ROK (run command enable), EB (phase B rotation direction detection), DISP (display limit), NO (no function) |
Output other functions | RUN (running signal), FA1 - FA5 (frequency arrival signal), OL, OL2 (overload pre-alert signal), OD (PID deviation error signal), AL (warning signal), OTQ (over/under torque threshold), UV (under voltage), TRQ (torque limit signal), RNT (running timeout), ONT (power ON timeout), THM (heat alarm), BRK (brake release), BER (brake error), ZS (0Hz detection), DSE (overspeed deviation), POK (positioning complete), ODc (analog voltage input disconnect), OIDc (analog current input disconnect), FBV (second stage PID output), NDc (network disconnection detection), LOG1 –LOG3 (Output signal logic), WAC (capacitor life warning), WAF (fan overheat warning) cool), FR (start contact), OHF (heatsink overheat warning), LOC (Low Load), MO1 - MO3 (common output for EzSQ), IRDY (inverter ready), FWR (forward operation), RVR (reverse operation), MJA (major fault), WCO (O window comparator), WCOI (O window comparator), FREF (frequency command source), REF (run command source), SETM (second motor idle), EDM (STO (safe torque off) performance monitoring), OP (control signal option), NO (no function) |
Protections functions | Overcurrent, overvoltage, undervoltage, overload, brake resistor overload, CPU error, memory error, external trip, USP error, ground fault detection at power-up, temperature error, internal communication error, driver error, thermistor error, brake error, safe stop, overload at low speed, modbus communication error, option error, encoder disconnection, overspeed, EzSQ command error, EzSQ loopback error, EzSQ execution error, |
Ambient_temp | -10 ℃-50 ℃ |
Ambient_humi | 20-90% RH. |
Ambient | -20℃- +65℃ |
Standard | IP20 |