View: 0

LM3 series - Genuine Hanyoung electric meter

In the increasingly developed industrial world, the effective control and management of electrical energy is a key factor in determining the sustainability of the production system. The LM3 series from Hanyoung is not just a regular electric meter but also the "heart" of every electrical system. With a wide viewing angle LCD display, easy-to-read white backlight and a rear length of only 68mm, the LM3 offers an optimal measurement experience. The IP66 protection structure against environmental factors, accurate measurement capabilities from RMS to AVG and support for MODBUS communication are the highlights that help the LM3 series overcome all technical challenges, ensuring high efficiency and reliability for businesses. Learn more about the LM3 Electric Meter Series through the article below!

1. General introduction of Hanyoung LM3 series electric meter


Đồng hồ đa năng LM3
- Using wide viewing angle LCD display and white backlight
- Short rear length 68 mm (LM3)
- Protection structure (Front of product): IP66
- Measurement selectable RMS and AVG
- Support MODBUS communication
- Maximum measurement input specifications (500 V d.c., 500 V a.c., 5A d.c., 5A a.c.)

2. Select product code LM3 series

Lựa chọn mã hàng LM3 series

Product code

Input specifications

Output specifications

Optional output

LM3-4AA-3NC-A

AC current

3 - NPN open collector output

RS-485 output (MODBUS-RTU)

LM3-4AA-3NT-A

AC current

3 - NPN open collector output

Transmission output (4 - 20 mA d.c.)

LM3-4AA-3PC-A

AC current

3 - PNP open collector output

RS-485 output (MODBUS-RTU)

LM3-4AA-3PT-A

AC current

3 - PNP open collector output

Transmission output (4 - 20 mA d.c.)

LM3-4AA-3R-A

AC current

3 - contact output

-

LM3-4AA-3RC-A

AC current

3 - contact output

RS-485 output (MODBUS-RTU)

LM3-4AA-3RT-A

AC current

3 - contact output

Transmission output (4 - 20 mA d.c.)

LM3-4AA-N-A

AC current

Show only

-

LM3-4AV-3NC-A

AC voltage

3 - NPN open collector output

RS-485 output (MODBUS-RTU)

LM3-4AV-3NT-A

AC voltage

3 - NPN open collector output

Transmission output (4 - 20 mA d.c.)

LM3-4AV-3PC-A

AC voltage

3 - PNP open collector output

RS-485 output (MODBUS-RTU)

LM3-4AV-3PT-A

AC voltage

3 - PNP open collector output

Transmission output (4 - 20 mA d.c.)

LM3-4AV-3R-A

AC voltage

3 - contact output

-

LM3-4AV-3RC-A

AC voltage

3 - contact output

RS-485 output (MODBUS-RTU)

LM3-4AV-3RT-A

AC voltage

3 - contact output

Transmission output (4 - 20 mA d.c.)

LM3-4AV-N-A

AC voltage

Show only

-

LM3-4DA-3NC-A

DC current

3 - NPN open collector output

RS-485 output (MODBUS-RTU)

LM3-4DA-3NT-A

DC current

3 - NPN open collector output

Transmission output (4 - 20 mA d.c.)

LM3-4DA-3PC-A

DC current

3 - PNP open collector output

RS-485 output (MODBUS-RTU)

LM3-4DA-3PT-A

DC current

3 - PNP open collector output

Transmission output (4 - 20 mA d.c.)

LM3-4DA-3R-A

DC current

3 - contact output

-

LM3-4DA-3RC-A

DC current

3 - contact output

RS-485 output (MODBUS-RTU)

LM3-4DA-3RT-A

DC current

3 - contact output

Transmission output (4 - 20 mA d.c.)

LM3-4DA-N-A

DC current

Show only

-

LM3-4DV-3NC-A

DC voltage

3 - NPN open collector output

RS-485 output (MODBUS-RTU)

LM3-4DV-3NT-A

DC voltage

3 - NPN open collector output

Transmission output (4 - 20 mA d.c.)

LM3-4DV-3PC-A

DC voltage

3 - PNP open collector output

RS-485 output (MODBUS-RTU)

LM3-4DV-3PT-A

DC voltage

3 - PNP open collector output

Transmission output (4 - 20 mA d.c.)

LM3-4DV-3R-A

DC voltage

3 - contact output

-

LM3-4DV-3RC-A

DC voltage

3 - contact output

RS-485 output (MODBUS-RTU)

LM3-4DV-3RT-A

DC voltage

3 - contact output

Transmission output (4 - 20 mA d.c.)

LM3-4DV-N-A

DC voltage

Show only

-

3. LM3 electric meter specifications

Model

LM3-DV

LM3-DA

LM3-AV

LM3-AA

Dimensions:

LM3 : 96(W) x 48(H) x 68(D) mm 

Power supply

100 - 240 V a.c. 50/60 Hz

Power consumption

▪LM3-N: 6 VA or less
▪LM3-3R/3RC: 10 VA or less

▪LM3-3RT: 11 VA or less
▪LM3-3NC/3PC: 9 VA or less

▪LM3-3NT/3PT: 10 VA or less

Input signal

DC voltage

DC current

AC voltage / frequency

AC current / frequency

Input range

500 V / 100 V

50 V / 10 V

5 V / 1 V

200 mV / 50 mV

5 A / 2 A

500 mA / 200 mA

50 mA / 4 - 20 mA

5 mA / 2 mA

500 V / 250 V

110 V / 50 V

20 V / 10 V

2 V / 1 V

5 A / 2 A

500 mA / 200 mA

50 mA / 20 mA

AC measurement method

AVG/RMS selective measurement

Input sampling period

50 ms

Input sampling method

OVER sampling method using continuous approximation A/D converter

Maximum allowed input

F.S. of each input range 110%

Frequency measurement range

0.2 ~ 9999 Hz (Frequency measurement range depends on decimal point position)

Display

▪ Negative LCD display
▪ 4 digits 2 rows
▪ PV (White)
▪ SV (Green)

Character size

▪ LM3 : 17.6 x 10.6 mm

Show maximum

-9999 ~ 9999

Show degree

▪[ 23 ℃ ± 5 ℃ ] - F.S. ± 0.1 % rdg ± 2 digit

▪[ 23 ℃ ± 5 ℃, 5 A ] - F.S. ± 0.3 % rdg ± 3 digit

▪[ 50 ℃ ~ -10 ℃ ] - F.S. ± 0.5 % rdg ±3 digit

▪[ 23 ℃ ± 5 ℃ ] - F.S. ± 0.3 % rdg ±3 digit

▪[ 23 ℃ ± 5 ℃, frequency ] - F.S. ± 0.1 % rdg ± 2 digit

▪[ 50 ℃ ~ -10 ℃ ] - F.S. ± 0.5 % rdg ± 3 digit

Output control

▪ Contact output: 3-phase, SPST (1a), 250 V a.c. 5 A
▪ Solid-state output: 3-phase, NPN or PNP open collector, 12 - 24 V d.c. 50mA or less

Relay life time

▪ Electrical (approx. 100,000 times, 250 V a.c. 5 A)
▪ Mechanical (approx
. 5 million times)

Optional output

▪ Transmit output (4-20 mA)
▪ RS-485 output

External input

▪ HOLD/ZERO Optional Input

▪ No-voltage input

▪ Short-circuit impedance: 300 Ω or less

▪ Residual voltage: 1 V or less

▪ Open impedance: 100 kΩ or more

Media

▪ Communication protocol: Modbus-RTU

▪ Communication method: RS-485 (2-wire half duplex)

▪ Communication speed: 2400 / 4800 / 9600 / 19200 / 38400 bps

Insulation resistance

100 ㏁ or more (500 V d.c. Mega standard, between the conductive connector and the case)

Withstand voltage

2000 V a.c. 60 Hz 1 min (between the mains connector and the case)

Noise

± 2 kV (Between active power terminals, Pulse width = 1 us, Square wave noise generated by noise simulator)

Anti-vibration

10 - 55 ㎐, Single amplitude 0.5 ㎜, 3-axis angle, 2 hours

Protective structure

▪ IP66 (front)
▪ Terminal block protection cover applied

Environmental temperature and humidity

-10 ~ 50 ℃, 35 ~ 85 % R.H.

Storage temperature

-20 ~ 65 ℃

4. LM3 series multi-function watch size

Kích thước đồng hồ đa năng LM3 series

5. Applications of Hanyoung LM3 electric meter

The application of the LM3 electric meter in industrial systems includes measuring and displaying DC/AC current and voltage values. This device is often integrated into the electrical cabinets of industrial automation systems, helping to monitor, control and manage important electrical parameters. Thanks to its accurate measurement and clear display, the LM3 meter supports engineers and technicians in checking and maintaining stable operation of the electrical system during operation and production.
Conclusion
In case you need to learn, need technical advice and order the LM3 Multimeter, please contact Amazen immediately via:
Hotline: 0934 399 068 - Sales: 0938 072 058
Email: amazen@amazen.com.vn

With a team of highly specialized technical support and sales consultants, our company is confident that it will bring customers the best shopping experience.